AReCoS

Controller evaluation

Evaluate the controller on your own refrigeration system.

For supermarket and cold-storage operators, and for manufacturers who build refrigeration equipment. The evaluation starts with your machine, measures a baseline before anything changes, and is designed to show what the controller does on that machine before any wider rollout.

Available for evaluation todayTerms agreed in writing before work starts

Two ways in

Run it on a system you operate, or build it into the equipment you sell.

Refrigeration operators

  • Evaluate the controller on an existing system, against a baseline measured on that system
  • Pilot costs, installation duties, data access and any share of savings agreed in writing first
  • Your building or plant system keeps the goals: setpoints, schedules and demand-response signals

Equipment manufacturers

  • The controller ships inside your equipment, licensed per unit, as part of your product
  • Controller hardware, sensor and actuator channel counts and the enclosure defined with you
  • Validation duties, and who owns what, set in the agreement

How it runs

Five steps, with the baseline before the controller.

  1. Review the systemRefrigerant, compressors, valves, cases or coils, the controls in place today and the safeties.
  2. Agree the interfacesWhich readings and actuators the controller takes, which controllers it replaces and which stay.
  3. Measure the baselineEnergy and temperatures on the system as it runs today, by a method agreed up front.
  4. Fit and runAReCoS fits a model to your machine and checks it against your own test data; then the controller runs it.
  5. Verify, then decideResults set against the baseline before anything goes further.

Where a case keeps a thermostatic expansion valve, the controller is designed to set the compressors, fans and defrost around it; the full optimum needs an electronic valve fitted in the retrofit (more).

Safeguards

The machine's own protection stays where it is.

Safeties stay independent
The machine's own safeties, hard-wired or on a compressor package's own panel, are not in the controller's path.
Fail-safe outputs
If the controller loses power, stops or is taken out of service, its outputs are designed to go to the fail-safe positions set for your machine; on a rack, normally the fallback it already has.
No command from the internet
Every control decision is designed to run on the equipment. An optional cloud connection is designed only to monitor (security).
Commissioning plan
Start-up, fallback and hand-back are written down with your team before the controller takes over.

What has been tested

What is on the record today, and what an evaluation is for.

Hardware test
The controller ran a vapor-compression system in cooling, reading its temperature sensors only and setting the compressor, electronic expansion valve, air blower and fan together (US 2024/0295337 A1, FIGS. 4 to 7).
Research agreement
Being tested with Oak Ridge National Laboratory under a research agreement (CRADA) supported by the U.S. Department of Energy, on rooftop-unit energy optimization.
Not yet run
On a supermarket rack, a CO2 system or an ammonia plant. Refrigeration plants and natural refrigerants are within the design scope, still to be validated: that is what an evaluation on your machine is for.

Every claim and its evidence: evidence and status.